{"id":932,"date":"2026-09-29T10:31:46","date_gmt":"2026-09-29T02:31:46","guid":{"rendered":"https:\/\/www.uptingclean.com\/?p=932"},"modified":"2026-09-29T10:31:46","modified_gmt":"2026-09-29T02:31:46","slug":"what-are-the-key-differences-between-an-iso-8-and-an-iso-7-cleanroom","status":"publish","type":"post","link":"https:\/\/www.uptingclean.com\/ja\/what-are-the-key-differences-between-an-iso-8-and-an-iso-7-cleanroom\/","title":{"rendered":"ISO 8\u30af\u30ea\u30fc\u30f3\u30eb\u30fc\u30e0\u3068ISO 7\u30af\u30ea\u30fc\u30f3\u30eb\u30fc\u30e0\u306e\u4e3b\u306a\u9055\u3044\u306f\u4f55\u3067\u3059\u304b\uff1f"},"content":{"rendered":"<p>An ISO 7 cleanroom is one classification level cleaner than an ISO 8 cleanroom, with substantially lower allowable concentrations of airborne particles. Under ISO 14644-1, the maximum concentration of particles measuring 0.5 \u03bcm or more is 352,000 particles per cubic metre for an ISO 7 cleanroom, compared to 3,520,000 particles per cubic metre for an ISO 8 cleanroom.<\/p>\n<p>Therefore, the difference is not simply a matter of room construction; it also affects airflow design, filtration strategy, pressure control, monitoring, personnel practices, validation, and operating costs. The primary references are ISO 14644-1:2015, &#8216;Cleanrooms and associated controlled environments \u2014 Part 1: Classification of air cleanliness by particle concentration and ISO 14644-2:2015, which addresses the ongoing monitoring of cleanroom performance.<\/p>\n<h2>ISO 7 vs. ISO 8: The Difference in One View<\/h2>\n<p>The easiest way to understand the distinction is to start with what ISO 14644 actually classifies. The standard classifies cleanrooms according to airborne particle concentration at specified particle sizes; it does not classify the room according to its wall material, HEPA filter brand, room appearance, or the number of air changes alone. ISO 14644-1 specifically uses particle sizes from 0.1 \u03bcm to 5 \u03bcm for its classification framework and relies on airborne particle counters at designated sampling locations.<\/p>\n<p>The numerical difference is substantial. At the commonly referenced 0.5 \u03bcm particle size, an ISO 7 environment allows one-tenth the concentration permitted for ISO 8. At 5 \u03bcm, the relationship is also ten-to-one. This is why an ISO 7 modular cleanroom normally requires a more demanding contamination-control strategy than an ISO 8 <strong><a href=\"https:\/\/www.uptingclean.com\/ja\/cleanroom-system\/\">modular cleanroom<\/a><\/strong>, even when the two rooms occupy similar physical spaces.<\/p>\n<table>\n<tbody>\n<tr>\n<td style=\"text-align: center;\"><strong><b>Cleanroom characteristic<\/b><\/strong><\/td>\n<td style=\"text-align: center;\"><strong><b>ISO 7<\/b><\/strong><\/td>\n<td style=\"text-align: center;\"><strong><b>ISO 8<\/b><\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Maximum particles \u22650.5 \u03bcm<\/td>\n<td style=\"text-align: center;\">352,000 particles\/m\u00b3<\/td>\n<td style=\"text-align: center;\">3,520,000 particles\/m\u00b3<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Maximum particles \u22655.0 \u03bcm<\/td>\n<td style=\"text-align: center;\">2,930 particles\/m\u00b3<\/td>\n<td style=\"text-align: center;\">29,300 particles\/m\u00b3<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Relative particle-control requirement<\/td>\n<td style=\"text-align: center;\">More stringent<\/td>\n<td style=\"text-align: center;\">Less stringent<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Typical design implication<\/td>\n<td style=\"text-align: center;\">Higher contamination-control demand<\/td>\n<td style=\"text-align: center;\">Moderate contamination-control demand<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Typical role<\/td>\n<td style=\"text-align: center;\">More sensitive production and controlled processes<\/td>\n<td style=\"text-align: center;\">Packaging, preparation and support processes<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Monitoring burden<\/td>\n<td style=\"text-align: center;\">Generally more demanding<\/td>\n<td style=\"text-align: center;\">Generally less demanding<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">HVAC\/airflow design<\/td>\n<td style=\"text-align: center;\">More intensive<\/td>\n<td style=\"text-align: center;\">Less intensive<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Operating cost<\/td>\n<td style=\"text-align: center;\">Usually higher<\/td>\n<td style=\"text-align: center;\">Usually lower<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Particle limits are based on ISO 14644-1 classification values; typical applications and system implications vary according to the process and regulatory environment.<\/p>\n<p>A crucial point for engineers and facility managers is that ISO 7 does not mean every aspect of the environment is automatically ten times better than ISO 8. The tenfold difference refers to specified airborne particle concentration limits, not temperature, humidity, microbial control, pressure differential, sterility, or overall product quality.<\/p>\n<h2>What Does an ISO 7 Cleanroom Mean?<\/h2>\n<p>An ISO 7 cleanroom is designed to maintain a low concentration of airborne particles under defined operating conditions. As the permissible particle concentration is much lower than in an ISO 8 environment, the room must control particle sources and provide sufficient filtered air to dilute and remove contamination.<\/p>\n<p>In practice, ISO 7 environments are often found in manufacturing or processing areas where airborne contamination could directly affect product performance. Examples include certain pharmaceutical manufacturing areas, medical device assembly operations, precision manufacturing, electronic processes, laboratories, and controlled preparation areas. The exact classification should always be derived from process risk and applicable regulatory requirements rather than industry name alone.<\/p>\n<p>For a modular cleanroom, ISO 7 places greater importance on the integrity of the enclosure. Wall and ceiling joints, doors, viewing windows, service penetrations, return-air paths, and connections around filtration equipment must all work together as one integrated system for controlling contamination. Even a high-quality panel cannot compensate for poor sealing or an unsuitable airflow arrangement.<\/p>\n<h2>What Does an ISO 8 Cleanroom Mean?<\/h2>\n<p>ISO 8 is a less stringent particle classification, but it is still a controlled environment, not an ordinary room with a few filters installed. The room must be designed, operated, cleaned, and monitored so that its airborne particle concentration remains within the specified classification under the conditions for which it is qualified.<\/p>\n<p>ISO 8 is commonly encountered in packaging, material preparation, controlled storage, certain food and cosmetic processes, medical-device support areas, gowning areas, and other operations where environmental control is required but the process does not justify the tighter particle limits of ISO 7. In a modular cleanroom project, ISO 8 can also serve as a support zone surrounding cleaner areas, helping establish a controlled transition between conventional manufacturing space and higher-grade environments.<\/p>\n<p>This distinction is important because a facility does not necessarily benefit from specifying ISO 7 everywhere. If a process only requires ISO 8, designing the entire space to ISO 7 may increase airflow demand, filtration requirements, energy consumption, maintenance requirements, and qualification work without providing a corresponding process benefit.<\/p>\n<figure style=\"width: 961px\" class=\"wp-caption alignnone\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/www.uptingclean.com\/wp-content\/uploads\/2026\/05\/%E8%A3%85%E9%85%8D%E5%BC%8F%E6%B4%81%E5%87%80%E5%AE%A4-1.webp\" alt=\"Cleanroom System\" width=\"961\" height=\"640\" \/><figcaption class=\"wp-caption-text\">Modular cleanroom<\/figcaption><\/figure>\n<h2>Airflow Is One of the Biggest Practical Differences<\/h2>\n<p>Although ISO 14644-1 establishes the classification of particles, it does not prescribe a single air-change rate for ISO classes 7 and 8. Instead, airflow requirements must be developed according to room volume, contamination generation, equipment, personnel load, filtration arrangement, airflow pattern, pressure relationships, and required cleanliness performance.<\/p>\n<p>Therefore, online comparisons stating that &#8216;ISO 7 always requires X air changes per hour and ISO 8 always requires Y&#8217; should be treated with caution. In a real modular cleanroom design, the engineering team needs to calculate and verify the airflow strategy, rather than simply selecting an air-change number from a generic table.<\/p>\n<p>For ISO 7, the lower particle limit generally means the system has less tolerance for contamination. Therefore, more careful distribution of filtered supply air, appropriate positioning of return air, effective room sealing, controlled personnel movement, and well-designed material transfer become increasingly important. ISO 8 still requires these controls, but the design can tolerate a higher particle concentration.<\/p>\n<h2>HEPA Filtration Alone Does Not Determine the ISO Class<\/h2>\n<p>A common misconception is that installing a HEPA filter automatically creates an ISO 7 or ISO 8 cleanroom. In reality, filtration is only one part of the system. The final classification depends on the airborne particle concentration measured in the room under the specified classification conditions.<\/p>\n<p>A modular cleanroom can use HEPA-filtered fan filter units, centralized air-handling systems, terminal HEPA housings, or combinations of these technologies. The important question is whether the complete system\u2014including air distribution, filtration, return paths, enclosure integrity, doors, penetrations, cleaning, and operating procedures\u2014can consistently achieve the intended classification.<\/p>\n<p>This becomes particularly relevant when upgrading an ISO 8 area to ISO 7. Simply adding more filter units may not solve the problem if the existing room has uncontrolled leakage, poor airflow distribution, excessive personnel traffic, unsuitable returns, or contamination sources inside the process.<\/p>\n<h2>Why Modular Cleanroom Construction Is Relevant to ISO 7 and ISO 8?<\/h2>\n<p>The term &#8216;modular cleanroom&#8217; describes an approach to construction rather than a cleanliness class. Depending on its engineering configuration, a modular cleanroom can be designed for ISO 8, ISO 7, or substantially cleaner environments.<\/p>\n<p>Prefabricated wall and ceiling systems provide controlled interfaces, repeatable dimensions, cleanable surfaces, and predictable installation procedures. Modular construction is particularly useful when a manufacturer needs to create a controlled environment within an existing factory, rather than constructing a new building from scratch.<\/p>\n<p>The main advantage is flexibility in project execution. Prefabricated components can be manufactured before installation and assembled on site. They can also be more readily modified or expanded than with some conventional construction approaches. Industry sources describe modular cleanrooms as systems comprising prefabricated walls, roof structures and filtered air equipment, which are assembled at the installation site.<\/p>\n<p>However, &#8216;modular&#8217; should never be confused with &#8216;automatically compliant&#8217;. A modular enclosure still requires suitable HVAC capacity, filtration, pressure relationships, sealing, environmental monitoring, qualification and operating procedures. ISO classification is ultimately demonstrated through performance measurements, not the construction label.<\/p>\n<h2>Pressure Control and Room Zoning Matter More as Cleanliness Requirements Increase<\/h2>\n<p>Particle control is strongly affected by how people and materials move between spaces. If a cleanroom has uncontrolled openings to a less-clean environment, contaminated air can enter whenever pressure relationships or door operation allow it.<\/p>\n<p>For this reason, ISO 7 and ISO 8 facilities frequently use combinations of airlocks, gowning areas, pass boxes, controlled doors, pressure monitoring, and zoning. The exact pressure differential is project-specific; ISO 14644-1 should not be interpreted as prescribing a single universal pressure value for every cleanroom application.<\/p>\n<p>An effective modular cleanroom therefore needs to be considered as a system of connected zones, rather than as an isolated room. For example, an ISO 8 preparation area may connect to an ISO 7 production room, with personnel and material flows deliberately arranged to minimize contamination transfer. ISO 14644-2 also emphasizes monitoring strategies and risk-based assessment rather than treating classification as a one-time measurement.<\/p>\n<h2>ISO 7 and ISO 8 Have Different Operational Demands<\/h2>\n<p>The physical design only accounts for half of the equation. Particles can be introduced into a cleanroom by people, materials, equipment, cleaning tools, packaging and maintenance activities.<\/p>\n<p>Therefore, an ISO 7 operation generally requires tighter control of gowning, access, material transfer, cleaning frequency, equipment placement and personnel behaviour than an ISO 8 operation. However, the appropriate procedures depend on the specific process: an ISO 8 room handling a particularly contamination-sensitive product may still require strict operating procedures, despite its less stringent particle classification.<\/p>\n<p>ISO 14644-2 is useful here as it focuses on establishing a monitoring plan that provides ongoing evidence of cleanroom performance. It calls for a risk-based approach, considering factors such as particle monitoring, pressure differential, airflow volume or velocity, calibration, and alert\/action levels and responses to deviations.<\/p>\n<h2>ISO 7 vs. ISO 8: Which One Should a Manufacturer Specify?<\/h2>\n<p>The right question is not simply \u201cIs ISO 7 better than ISO 8?\u201d A more useful engineering question is: What is the minimum classification that reliably protects the product, process, and applicable regulatory requirements?<\/p>\n<p>For a process with limited sensitivity to airborne contamination, ISO 8 may provide an appropriate balance between environmental control and operating complexity. For processes where particle contamination has a greater potential impact on exposed products or critical operations, ISO 7 may be specified.<\/p>\n<table>\n<tbody>\n<tr>\n<td style=\"text-align: center;\"><strong><b>Decision factor<\/b><\/strong><\/td>\n<td style=\"text-align: center;\"><strong><b>ISO 7 consideration<\/b><\/strong><\/td>\n<td style=\"text-align: center;\"><strong><b>ISO 8 consideration<\/b><\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Product sensitivity<\/td>\n<td style=\"text-align: center;\">Suitable where tighter particle control is required<\/td>\n<td style=\"text-align: center;\">Suitable where moderate control is adequate<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Airborne contamination risk<\/td>\n<td style=\"text-align: center;\">Lower allowable particle concentration<\/td>\n<td style=\"text-align: center;\">Higher allowable particle concentration<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">HVAC demand<\/td>\n<td style=\"text-align: center;\">Usually greater<\/td>\n<td style=\"text-align: center;\">Usually lower<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Energy demand<\/td>\n<td style=\"text-align: center;\">Generally higher<\/td>\n<td style=\"text-align: center;\">Generally lower<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Personnel control<\/td>\n<td style=\"text-align: center;\">More stringent operating discipline may be required<\/td>\n<td style=\"text-align: center;\">Controlled but potentially less demanding<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Material transfer<\/td>\n<td style=\"text-align: center;\">Often requires carefully planned flows<\/td>\n<td style=\"text-align: center;\">Controlled transfer remains important<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Validation\/qualification<\/td>\n<td style=\"text-align: center;\">More demanding performance target<\/td>\n<td style=\"text-align: center;\">Less stringent particle target<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\">Future process requirements<\/td>\n<td style=\"text-align: center;\">Provides tighter particle-control capability<\/td>\n<td style=\"text-align: center;\">May be easier and less costly when ISO 8 is sufficient<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The final specification should be based on the product, process, contamination risk, applicable regulations, equipment, room occupancy, material flow, and expected future production requirements. Over-classifying a facility can create unnecessary capital and operating costs, while under-classifying it can create contamination and compliance problems.<\/p>\n<h2>Testing and Monitoring: Classification Is Not a One-Time Construction Check<\/h2>\n<p>A cleanroom should not be considered successful just because its HVAC system is operational and the required particle count was achieved during commissioning. The room must maintain the required environmental performance during operation.<\/p>\n<p>ISO 14644-1 establishes the classification methodology, while ISO 14644-2 addresses the monitoring strategy required to provide ongoing evidence of performance. The latter explicitly distinguishes ongoing monitoring from initial or periodic classification exercises, recommending the use of monitoring data to identify trends and respond to adverse conditions.<\/p>\n<p>For ISO Class 7 or 8 modular cleanrooms, the monitoring programme may therefore incorporate particle counts, pressure differentials, airflow-related measurements, filter condition, and temperature and humidity where relevant, as well as other parameters determined by the facility&#8217;s risk assessment. This approach provides operators with a much clearer indication of whether the cleanroom remains under control between formal classification tests.<\/p>\n<figure style=\"width: 2816px\" class=\"wp-caption alignnone\"><img decoding=\"async\" src=\"https:\/\/www.uptingclean.com\/wp-content\/uploads\/2026\/05\/20260513-173641.webp\" alt=\"Cleanroom System\" width=\"2816\" height=\"1536\" \/><figcaption class=\"wp-caption-text\">Modular cleanroom<\/figcaption><\/figure>\n<h2>Common Mistakes When Comparing ISO 7 and ISO 8<\/h2>\n<p>One frequent mistake is treating ISO 7 and ISO 8 as two fixed equipment packages. There is no universal \u201cISO 7 machine\u201d or \u201cISO 8 machine\u201d; the classification is the measured cleanliness performance of the controlled environment.<\/p>\n<p>Another mistake is relying on air-change rates without considering particle generation. A room with high personnel activity and particle-generating equipment may behave very differently from a lightly occupied room with the same nominal air-change rate. Similarly, a high-efficiency filter cannot compensate indefinitely for poor room sealing, uncontrolled traffic, or badly positioned return air.<\/p>\n<p>A third mistake is assuming that an ISO classification automatically establishes sterility or microbial control. ISO 14644-1 concerns airborne particle concentration and explicitly does not characterize the physical, chemical, radiological, viable, or other nature of airborne particles.<\/p>\n<h2>The Bottom Line for Modular Cleanroom Projects<\/h2>\n<p>The main difference between ISO 7 and ISO 8 relates to the concentration of airborne particles. ISO 7 allows for a substantially lower concentration of particles than ISO 8 at the specified classification sizes. This numerical distinction has practical implications for airflow design, enclosure integrity, contamination control procedures, monitoring, and operating costs.<\/p>\n<p>When evaluating a modular cleanroom, manufacturers should therefore select the classification as part of an integrated engineering process, rather than choosing it independently from the building design. While a well-designed ISO 8 modular cleanroom may be appropriate for one process, another process may require ISO 7. What matters is whether the selected class can consistently meet the actual contamination control objective under real operating conditions.<\/p>\n<h2>FAQ: Modular Cleanroom<\/h2>\n<ol>\n<li>What is a modular cleanroom?<\/li>\n<\/ol>\n<p>A modular cleanroom is a controlled environment assembled from prefabricated components such as cleanroom wall panels, ceilings, doors, windows, and filtered-air systems. Its cleanliness classification can range from ISO 8 to ISO 7 and beyond, depending on the complete system design.<\/p>\n<ol start=\"2\">\n<li>Can a modular cleanroom achieve ISO 7?<\/li>\n<\/ol>\n<p>Yes, a properly engineered modular cleanroom can be designed and qualified to achieve ISO 7 classification. The result depends on the enclosure, airflow distribution, filtration, pressure control, contamination sources, and operating procedures rather than the modular construction method alone.<\/p>\n<ol start=\"3\">\n<li>What is the difference between ISO 7 and ISO 8 modular cleanrooms?<\/li>\n<\/ol>\n<p>The principal difference is the allowable airborne particle concentration, with ISO 7 permitting substantially fewer particles than ISO 8. This difference generally leads to tighter airflow, filtration, sealing, monitoring, and operational requirements.<\/p>\n<ol start=\"4\">\n<li>Is ISO 7 more expensive than ISO 8?<\/li>\n<\/ol>\n<p>An ISO 7 cleanroom will generally require more intensive environmental control and can therefore have higher capital and operating costs. The actual cost depends on room size, HVAC configuration, filtration, equipment, materials, utilities, validation, and local construction conditions.<\/p>\n<ol start=\"5\">\n<li>How do I choose between ISO 7 and ISO 8?<\/li>\n<\/ol>\n<p>The selection should start with product sensitivity, process contamination risk, applicable regulations, personnel and material flows, and required production conditions. The objective is to specify the classification that reliably meets the process requirement rather than automatically selecting the cleanest available class.<\/p>\n<ol start=\"6\">\n<li>Does ISO 7 mean the room is sterile?<\/li>\n<\/ol>\n<p>No, ISO 7 is an airborne particle cleanliness classification and does not by itself establish sterility or microbial control. ISO 14644-1 specifically distinguishes particle concentration classification from the physical, chemical, radiological, viable, and other characteristics of airborne particles.<\/p>\n<h2>Conclusion<\/h2>\n<p>Ultimately, the difference between an ISO 7 and an ISO 8 cleanroom comes down to the level of airborne particle control required by the process. ISO 7 allows for significantly fewer airborne particles than ISO 8, and generally requires more carefully engineered airflow, filtration, pressure control, enclosure integrity, monitoring, and operating procedures. Therefore, when considering a modular cleanroom, manufacturers should select the classification according to product sensitivity, contamination risk, regulatory requirements, personnel and material flow, and long-term production needs, rather than simply choosing the higher classification. When the cleanroom structure, HVAC system, filtration, monitoring programme, and daily operating practices are designed as one integrated system, a properly designed and validated ISO 7 or ISO 8 environment can provide effective contamination control.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u7c92\u5b50\u9650\u754c\u3001\u7a7a\u6c17\u6e05\u6d44\u5ea6\u3001\u6c17\u6d41\u8981\u4ef6\u3001\u74b0\u5883\u5236\u5fa1\u3001\u304a\u3088\u3073\u7ba1\u7406\u3055\u308c\u305f\u88fd\u9020\u74b0\u5883\u306b\u304a\u3051\u308b\u4e00\u822c\u7684\u306a\u7528\u9014\u3092\u6bd4\u8f03\u3059\u308b\u3053\u3068\u3067\u3001ISO 8\u30af\u30ea\u30fc\u30f3\u30eb\u30fc\u30e0\u3068ISO 7\u30af\u30ea\u30fc\u30f3\u30eb\u30fc\u30e0\u306e\u4e3b\u306a\u9055\u3044\u3092\u7406\u89e3\u3057\u307e\u3057\u3087\u3046\u3002<\/p>","protected":false},"author":1,"featured_media":710,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[68],"tags":[135,137,138,136],"class_list":["post-932","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news","tag-modular-cleanroom-manufacturer","tag-modular-cleanroom-solutions","tag-modular-cleanroom-supplier","tag-modular-cleanroom-systems"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.uptingclean.com\/ja\/wp-json\/wp\/v2\/posts\/932","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.uptingclean.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.uptingclean.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.uptingclean.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.uptingclean.com\/ja\/wp-json\/wp\/v2\/comments?post=932"}],"version-history":[{"count":0,"href":"https:\/\/www.uptingclean.com\/ja\/wp-json\/wp\/v2\/posts\/932\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.uptingclean.com\/ja\/wp-json\/wp\/v2\/media\/710"}],"wp:attachment":[{"href":"https:\/\/www.uptingclean.com\/ja\/wp-json\/wp\/v2\/media?parent=932"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.uptingclean.com\/ja\/wp-json\/wp\/v2\/categories?post=932"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.uptingclean.com\/ja\/wp-json\/wp\/v2\/tags?post=932"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}